- housing: plastic
- mounting: DIN rail TH-35
- space requirement: 1 division unit
- contact material: AgSnO2
- suitable for use with inductive loads
- number of consumers (buttons): 3
- rated voltage: 250V AC
- power: 16A
- switching capacity: 1W - 4000W
- switching frequency: max. 600 cycles/h
- contact resistance: = 100mOhm
- switching frequency: > 0.5 x 10^5
- mechanical resistance (cycles): > 3 x 10^7
- adjustment knob for time function, time range and time setting (extra time)
- 5 time functions, 10 time ranges
- time Functions: ON, OFF, AUTO, R, Wi + Extra Time
- Explanation of the individual functions can be found under "Note".
- time ranges: 1s, 10s, 20s, 30s, 1min, 1.5min, 2min, 3min, 5min, 10min.
- accuracy of time setting: ± 5%
- green LED status display U for voltage and time measurement (flashing)
- yellow LED status indicator R for the status of the output relay ON/OFF
- connection via screw terminals
- connection cable cross-section: max. 2.5mm²
- dimensions: approx. 64.6x17.5x90mm (h-w-d)
- weight: about 66g
- working temperature: -20°C ... +50°C
- storage humidity: < 85%
- protection class: IP20
- all details according to the manufacturer
Technical info
indoor area Accessories plastic 250V IP20
Explanation of time functions ON: permanent activation of the contact
Switching on the supply voltage U causes the contact R to be permanently switched on. Switching the control contact S on and off has no effect on the status of the contact R.
OFF: permanent deactivation of the contact
Switching on the supply voltage U does not cause any change in the status of the relay - the contact R remains permanently switched off. Switching control contact S on and off has no effect on the status of contact R.
AUTO: switch on at set time
Every time the supply voltage U is switched on or every time the control contact S is closed when the supply voltage U is switched on, the contact R is switched on immediately for an adjustable time T. After the time T has been measured, the contact R is switched off. The opening and closing of the control contact S during the measurement of the time T does not affect the implemented function. If the AUTO function is enabled in the ”Extra Time” mode, after measuring the time T, the contact R is switched off for 1s and then switched on again for 10s. After measuring the time of 10s, the contact R is switched off.
R: Shutdown delay
The input of the timing relay is permanently supplied with the voltage U. Closing the control contact S leads to immediate switching on of the execution relay R. Opening of the control contact S counts the set delay time for switching off the execution relay R. After measuring the time T, the execution relay R switches off. If the control contact S is closed before the time T has elapsed, then the previously measured time is reset to 0 and the execution relay remains switched on. The delay of the execution relay R begins with further opening of the control contact S. If the R function is enabled in the ”Extra Time” mode, after the counting of the time T, the contact R is switched off for 1s, and then it is switched on again for 10s. After measuring the time of 10 s, the contact R is switched off.
Wi: controlled switching on for a set time with switching off function
The input of the timing relay is permanently supplied with the voltage U. Closing the control contact S leads to the immediate switching on of the execution relay R for the set time T. After the time T counts, the execution relay R turns off. The execution relay R is switched on again for the time T by closing the control contact S again. If the control contact S closes again during the measurement of the time T, the execution relay is switched off immediately and the measured time is deleted. The opening of the control contact S during the measurement of the time T does not affect the implemented function. If the Wi function is enabled in the ”Extra Time” mode, after measuring the time T, the contact R is switched off for 1s and then switched on again for 10s. After measuring the time of 10s, the contact R is switched off.
Safety instructions and important information
- Connection or installation must be performed only by qualified staff.
- Never exceed the maximum connected load.
- No assembly near or even on combustible materials such as wood, etc.
- The 230V components must be connected with at least 1.5mm² cable.
- Please be aware of the appropriate health and safety regulations within your country.
- No installation on or in the vicinity (50cm) of flammable materials (flash point >200°C).
- Turn off or disconnect from the main circuit before starting to work. Otherwise there is a danger to LIFE.
- A professional electrician should check connection or installation before switching on power again and operating the device.
* all prices including VAT and excluding shipping cost; minimum order 10 euros
** Valid for deliveries for standard shipping within Germany. Delivery times for other countries and information on the calculation of delivery, see here.
Unser Online-Shop verwendet Cookies, die uns helfen, unser Angebot zu verbessern und unseren Kunden den bestmöglichen Service zu bieten. Indem Sie auf "Akzeptieren" klicken, erklären Sie sich mit unseren Cookie-Richtlinien einverstanden.
Cookies für Tools, die anonyme Daten über Website-Nutzung und -Funktionalität sammeln. Wir nutzen die Erkenntnisse, um unsere Produkte, Dienstleistungen und das Benutzererlebnis zu verbessern.
Support
Cookies für Tools, die interaktive Services wie Chat-Support und Kunden-Feedback-Tools unterstützen.
Werbung
Cookies für anonyme Informationen, die wir sammeln, um Ihnen nützliche Produkte und Dienstleistung empfehlen zu können.
Grundlegendes
Cookies für Tools, die wesentliche Services und Funktionen ermöglichen. Diese Option kann nicht abgelehnt werden.